The restrictors incorporate a precision synthetic sapphire orifice which is fitted within a main body. The sapphire orifice is a stable, accurate flow restrictor. Standard sizes range from .0012" to .0252" orifice diameter in 32 increments.
Unit of Measure

Material

N/A Nylon

Nominal Orifice Size

N/A 58

CV

N/A 0.031

Orifice Material

N/A Synthetic Sapphire

Maximum Operating Pressure Gauge

N/A 100 psig

Connection A

N/A .128" Press-Fit Insert

Screened

N/A None

Orifice Diameter

N/A 0.0228 in0.58 mm

Total Length

N/A 0.306 in

Maximum Outside Diameter

N/A 0.129 in

Minimum Outside Diameter

N/A 0.128 in

Orifice Diameter Accuracy

N/A ±0.0003 in

Press Fit into Bore

N/A 0.125 to 0.126 in

N/A

  • Precision Flow Control - Gases or Liquids
  • Accurate Timing in Pneumatic or Hydraulic Circuits
  • Pressure Dividing Circuits and Pneumatic Resistance Bridges
  • Impedance Matching
  • Uni-directional Flow

Air Flow at Pressure - Standard Liters Per Minute (SLPM)_Sapphire

N/A 1 psig: 1.38 5 psig: 3.26 10 psig: 4.43 15 psig: 5.55 20 psig: 6.55 25 psig: 7.53 30 psig: 8.48 40 psig: 10.4 50 psig: 12.3 60 psig: 14.2 70 psig: 16.0 80 psig: 17.9 90 psig: 19.7 100 psig: 21.6

Air Flow at Vacuum - Standard Liters Per Minute (SLPM)_Sapphire

N/A 5 In. Hg.: 2.13 10 In. Hg.: 2.55

Air Flow at Vacuum, Choked Flow - Standard Liters Per Minute (SLPM)_Sapphire

N/A 15 In. Hg.: 2.77 20 In. Hg.: 2.77 30 In. Hg.: 2.77

Air Flow at Pressure - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 1 psig: 2.92 5 psig: 6.90 10 psig: 9.39 15 psig: 11.8 20 psig: 13.9 25 psig: 16.0 30 psig: 18.0 40 psig: 22.0 50 psig: 26.1 60 psig: 30.1 70 psig: 33.9 80 psig: 37.9 90 psig: 41.7 100 psig: 45.8

Air Flow at Vacuum - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 5 In. Hg.: 4.51 10 In. Hg.: 5.40

Air Flow at Vacuum, Choked Flow - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 15 In. Hg.: 5.87 20 In. Hg.: 5.87 30 In. Hg.: 5.87