The restrictors incorporate a precision synthetic sapphire orifice which is fitted within a main body. The sapphire orifice is a stable, accurate flow restrictor. Standard sizes range from .0012" to .0252" orifice diameter in 32 increments.
Unit of Measure

Material

N/A 303 SS

Orifice Material

N/A Sapphire/Nylon Sleeve

Nominal Orifice Size

N/A 5

CV

N/A 0.00009

Maximum Operating Pressure

N/A 100 psig

Connection A

N/A 1/8" NPT Male

Connection B

N/A 1/8" NPT Male

Screened

N/A Screened

Orifice Diameter

N/A 0.002 in

Orifice Diameter Accuracy

N/A ±0.0005 in

Width Across Flats (Hex)

N/A 7/16 in

Total Length

N/A 0.970 in

N/A

  • Precision Flow Control - Gases or Liquids
  • Accurate Timing in Pneumatic or Hydraulic Circuits
  • Pressure Dividing Circuits and Pneumatic Resistance Bridges
  • Impedance Matching
  • Uni-directional Flow

Air Flow at Pressure - Standard Liters Per Minute (SLPM)_Sapphire

N/A 1 psig: 0.010 5 psig: 0.027 10 psig: 0.036 15 psig: 0.046 20 psig: 0.055 25 psig: 0.063 30 psig: 0.072 40 psig: 0.089 50 psig: 0.106 60 psig: 0.123 70 psig: 0.141 80 psig: 0.158 90 psig: 0.175 100 psig: 0.193

Air Flow at Vacuum - Standard Liters Per Minute (SLPM)_Sapphire

N/A 5 In. Hg.: 0.014 10 In. Hg.: 0.018

Air Flow at Vacuum, Choked Flow - Standard Liters Per Minute (SLPM)_Sapphire

N/A 15 In. Hg.: 0.021 20 In. Hg.: 0.021 30 In. Hg.: 0.021

Air Flow at Pressure - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 1 psig: 0.021 5 psig: 0.056 10 psig: 0.076 15 psig: 0.097 20 psig: 0.117 25 psig: 0.133 30 psig: 0.152 40 psig: 0.189 50 psig: 0.225 60 psig: 0.261 70 psig: 0.299 80 psig: 0.335 90 psig: 0.371 100 psig: 0.409

Air Flow at Vacuum - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 5 In. Hg.: 0.029 10 In. Hg.: 0.039

Air Flow at Vacuum, Choked Flow - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 15 In. Hg.: 0.045 20 In. Hg.: 0.045 30 In. Hg.: 0.045