The restrictors incorporate a precision synthetic sapphire orifice which is fitted within a main body. The sapphire orifice is a stable, accurate flow restrictor. Standard sizes range from .0012" to .0252" orifice diameter in 32 increments.
Unit of Measure

Orifice Material

N/A Sapphire/Nylon Sleeve

Material

N/A Brass

Nominal Orifice Size

N/A 34

CV

N/A 0.004

Maximum Operating Pressure

N/A 100 psig

Connection A

N/A 1/8" NPT Male

Connection B

N/A 1/16" ID Barb

Screened

N/A None

Orifice Diameter

N/A 0.0134 in

Orifice Diameter Accuracy

N/A ±0.0003 in

Width Across Flats (Hex)

N/A 7/16 in

Total Length

N/A 0.875 in

Application

N/A
  • Precision Flow Control - Gases or Liquids
  • Accurate Timing in Pneumatic or Hydraulic Circuits
  • Pressure Dividing Circuits and Pneumatic Resistance Bridges
  • Impedance Matching
  • Uni-directional Flow

Air Flow at Pressure - Standard Liters Per Minute (SLPM)_Sapphire

N/A 1 psig: 0.446 5 psig: 1.06 10 psig: 1.45 15 psig: 1.85 20 psig: 2.20 25 psig: 2.52 30 psig: 2.84 40 psig: 3.46 50 psig: 4.08 60 psig: 4.69 70 psig: 5.31 80 psig: 5.93 90 psig: 6.56 100 psig: 7.18

Air Flow at Pressure - Standard Liters Per Minute (SLPM)_Sapphire

N/A 5 In. Hg.: 0.673 10 In. Hg.: 0.833

Air Flow at Vacuum - Standard Liters Per Minute (SLPM)_Sapphire

N/A 15 In. Hg.: 0.921 20 In. Hg.: 0.921 30 In. Hg.: 0.921

Air Flow at Vacuum, Choked Flow - Standard Liters Per Minute (SLPM)_Sapphire

N/A 1 psig: 0.945 5 psig: 2.25 10 psig: 3.07 15 psig: 3.92 20 psig: 4.66 25 psig: 5.34 30 psig: 6.02 40 psig: 7.33 50 psig: 8.64 60 psig: 9.94 70 psig: 11.3 80 psig: 12.6 90 psig: 13.9 100 psig: 15.2

Air Flow at Pressure - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 5 In. Hg.: 1.43 10 In. Hg.: 1.76

Air Flow at Vacuum - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 15 In. Hg.: 1.95 20 In. Hg.: 1.95 30 In. Hg.: 1.95