Fine screens are used to protect orificesand other critical components from theoccasional particles that enter the fluidduring installation or otherwise. They arenot intended to replace normal filtrationequipment, but rather to augment the protectionof critical components in fluid controlsystems.Four sizes of screen particle retention areoffered; 10, 15, 25 and 100 microns. Thestainless steel wire screens do not introduceloose particles into the fluid stream.The screens are thoroughly cleaned toprevent inadvertent introduction of contaminants.
Unit of Measure

Material

N/A 316 SS

CV

N/A 0.009

Maximum Operating Pressure

N/A 4000 psig

Maximum Differential Pressure Across Screen

N/A 4000 psig

Maximum Pressure Differential

N/A 100 psig

Particle Retention

N/A 10 µ0.0004 in

Connection A

N/A 1/4" OD Tube Compression

Connection B

N/A 1/4" OD Tube

N/A

    In-line screens are suitable for use with liquids or gases compatible with the materials of construction. The screens protect critical components such as orifices from clogging or reducing flow rate. Applications for in-line screens include protection of:
  • Precision Orifices
  • Pneumatic Transducers
  • Gas and Liquid Flow Instruments
  • Medical Devices
  • Filling and Purging Systems
  • Pneumatic Timers
  • Transmitters
  • Pneumatic Transmission Lines
  • Hydraulic Controls
  • Leak Test Equipment
  • Flow Measurement Devices

Orifice Diameter

N/A 0 in

Width Across Flats (Hex)

N/A 9/16 in

Width Across Flats (Hex) 2

N/A 1/2 in

N/A

  • High Pressure Capability
  • Bi-directional Flow
  • Economical Precision Orifice
  • Repeatable Orifice Size and Shape
  • Predictable Flow Rate