• The Precision Micro-Orifices® are constructed of brass or stainless steel with orifice sizes from .0003" to .005" diameter. The orifices are used to accurately meter very low flow rates of gases or liquids.
Unit of Measure

Material

N/A Brass

Nominal Orifice Size

N/A 5

CV

N/A 0.000545

Maximum Operating Pressure Gauge

N/A 2000 psig

Connection

N/A 0.258/0.259" Press-Fit Insert

Screened

N/A None

Orifice Diameter

N/A 0.005 in

Total Length

N/A 0.156 in

Outside Diameter

N/A 0.258/0.259 in

N/A

  • Precision metering of very low flow rates – gases
  • Standard for flow or leak rates
  • Accurate timing in pneumatic circuits
  • Flow limiting

Features

N/A
  • High temperature capability (Type BLP, IBLP, K4LP, IALP)
  • High pressure capability (Type BLP, K4LP, IBLP, IALP)
  • Bi-directional flow
  • High accuracy
  • NIST traceable
  • Optional in-line screens available (except Type IBLP, IALP)
  • Orifice calibration available

Accuracy

N/A
    Standard Precision Micro-Orifices®are produced with very accurate characteristics and are production tested at an air supply pressure of 25 psig. The Flow Data tab lists the nominal flow at 25 psig and the accuracy of the measured flow for each orifice size.

Calibration

N/A
    Measured air flow data is optionally available. Twenty flow data points, over the specified supply pressure range, are measured with NIST traceable instruments.

Custom Orifice Sizes

N/A
    Custom orifice sizes, .0003" diameter and larger, can be produced to exacting air pressure and flow specifications. Using electronic pressure and flow measuring equipment that is NIST traceable, the custom Micro-Orifices® are produced to customer specifications. These custom orifices are available in types BLP, MLP, QXLP, IBLP, K4LP, IALP and Y2LPSS. A certificate of compliance to customer specifications is provided for all custom Micro-Orifices®. Contact factory for further details.

Ordering Information

N/A
    Identify the part number of Micro-Orifices® using the complete detail on the chart at right. See examples also. For orifice assemblies without optional screens, use the base number only. For assemblies that include screens, add the suffixes shown in the table. Both inlet and outlet screens are rated for 15 microns.

Air Flow Pressure at Standard Cubic Centimeters per Minute (SCCM)

N/A 5 psig: 144 10 psig: 203 15 psig: 253 20 psig: 299 25 psig: 344 30 psig: 390 40 psig: 482 50 psig: 570 60 psig: 662 70 psig: 753 80 psig: 845 90 psig: 938 100 psig: 1036

Flow Accuracy at Pressure - Standard Cubic Centimeters per Minute (SCCM)

N/A 25 psig: ± 20

Flow Data Status

N/A Generic