    The restrictors incorporate a precision synthetic sapphire orifice which is fitted within a main body. The sapphire orifice is a stable, accurate flow restrictor. Standard sizes range from .0012" to .0252" orifice diameter in 32 increments.
Unit of Measure

Specifications

Material

316 SS

Nominal Orifice Size

17

CV

0.0011

Orifice Material

Synthetic Sapphire/Nylon Sleeve

Maximum Operating Pressure

100 psig

Connection A

1/4" OD Tube Compression

Connection B

1/4" OD Tube Compression

Screened

None

Dimensions

Orifice Diameter

0.0067 in0.17 mm

Width Across Flats (Hex)

9/16 in

Total Length

1.61 in

Width Across Flats (Hex) 2

1/2 in

Orifice Diameter Accuracy

±0.0003 in

Application

N/A

  • Precision Flow Control - Gases or Liquids
  • Accurate Timing in Pneumatic or Hydraulic Circuits
  • Pressure Dividing Circuits and Pneumatic Resistance Bridges
  • Impedance Matching
  • Uni-directional Flow

Flow Data

Air Flow at Pressure - Standard Liters Per Minute (SLPM)_Sapphire

1 psig: 0.120 5 psig: 0.273 10 psig: 0.382 15 psig: 0.482 20 psig: 0.569 25 psig: 0.654 30 psig: 0.710 40 psig: 0.88 50 psig: 1.05 60 psig: 1.23 70 psig: 1.40 80 psig: 1.57 90 psig: 1.75 100 psig: 1.92

Air Flow at Vacuum - Standard Liters Per Minute (SLPM)_Sapphire

5 In. Hg.: 0.169 10 In. Hg.: 0.217

Air Flow at Vacuum, Choked Flow - Standard Liters Per Minute (SLPM)_Sapphire

15 In. Hg.: 0.235 20 In. Hg.: 0.235 30 In. Hg.: 0.235

Air Flow at Pressure - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

1 psig: 0.254 5 psig: 0.577 10 psig: 0.809 15 psig: 1.02 20 psig: 1.21 25 psig: 1.39 30 psig: 1.50 40 psig: 1.86 50 psig: 2.22 60 psig: 2.61 70 psig: 2.97 80 psig: 3.33 90 psig: 3.71 100 psig: 4.07

Air Flow at Vacuum - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

5 In. Hg.: 0.358 10 In. Hg.: 0.460

Air Flow at Vacuum, Choked Flow - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

15 In. Hg.: 0.498 20 In. Hg.: 0.498 30 In. Hg.: 0.498