This panel controls a liquid level within the deadband of a single pneumatic float valve. It can be configured for pump-up or pump-down control when used in conjunction with a normally closed pneumatic float valve (pump down) or a normally open pneumatic float valve (pump up). The dead-band of the pneumatic float valve is approximately ¼” – ½”. 
                
            
                    Unit of Measure
                    
               
        
            
                                                                                Description | 
                                                                        N/A Includes inlet filter, regulator and gage assembly | 
                                                                                Operation | 
                                                                        N/A A pneumatic control panel | 
                                                                                Box Dimensions | 
                                                                        N/A 4 x 4 x 2-5/8 in | 
                                                                                Inlet Air Pressure to Regulator | 
                                                                        N/A 50 to 125 psig | 
                                                                                Normal Pressure Setting | 
                                                                        N/A 50 to 100 psig | 
                                                                                Pneumatic Indicator | 
                                                                        N/A 1 in diameter red/green | 
                                                                                Manual Control | 
                                                                        N/A OFF/ON Toggle Valve | 
                                                                                Air Filtration | 
                                                                        N/A Air should be dry and filtered to 5 microns | 
                                                                                Output Air Signal | 
                                                                        N/A 50-100 psig (same as regulator pressure setting) | 
                                                                                Output Signal | 
                                                                        N/A 50-100 psig (same as regulator pressure setting) | 
                                                                                Control Action | 
                                                                        N/A OFF/ON Toggle Valve | 
                                                                                Minimum Input Pressure | 
                                                                        N/A 50 psig | 
                                                                                Maximum Input Pressure | 
                                                                        N/A 125 psig | 
                                                                                Minimum Operating Pressure | 
                                                                        N/A 50 psig | 
                                                                                Maximum Operating Pressure | 
                                                                        N/A 100 psig | 
                                                                                Operation | 
                                                                        N/A A pneumatic control panel | 
                                                                                Connection A | 
                                                                        N/A 5/32" OD Tube Push-Lock | 
        