Checked Orifices, Ball Type, Coupling
Checked Orifices, Ball Type: UNF/UNC
-
Checked orifices are a series arrangement of a precision orifice, a ball check valve and an optional screen. The all metal assemblies are made of brass or stainless steel. Gas or liquid can flow in one direction only, at a rate established by the metering orifice. Reverse pressure differential does not result in reverse flow. Standard sizes are 10-32, 1/8" NPT and 1/4" NPT. Custom requirements will be reviewed for large quantity applications.
Clear
Filter
Orifice Diameter (in)
Material
Nominal Orifice Size
CV
Cracking Pressure (psig)
Connection
Screened
Part Number |
Orifice Diameter |
Material |
CV |
Maximum Fitting PRESSURE |
DIFFERENTIAL CRACK PRESSURE |
Screened |
Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|
FIFLCS-31-2-SS | Orifice Diameter N/A 0.031 in | Material N/A 303 SS | CV N/A 0.022 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-31-10-SS | Orifice Diameter N/A 0.031 in | Material N/A 303 SS | CV N/A 0.022 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-32-10-SS | Orifice Diameter N/A 0.032 in | Material N/A 303 SS | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-32-2-SS | Orifice Diameter N/A 0.032 in | Material N/A 303 SS | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-32-0-SS | Orifice Diameter N/A 0.032 in | Material N/A 303 SS | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-32-10-BR | Orifice Diameter N/A 0.032 in | Material N/A Brass | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-32-2-BR | Orifice Diameter N/A 0.032 in | Material N/A Brass | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-32-0-BR | Orifice Diameter N/A 0.032 in | Material N/A Brass | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLC-32-10-SS | Orifice Diameter N/A 0.032 in | Material N/A 303 SS | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-32-2-SS | Orifice Diameter N/A 0.032 in | Material N/A 303 SS | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-32-0-SS | Orifice Diameter N/A 0.032 in | Material N/A 303 SS | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-32-10-BR | Orifice Diameter N/A 0.032 in | Material N/A Brass | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-32-2-BR | Orifice Diameter N/A 0.032 in | Material N/A Brass | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-32-0-BR | Orifice Diameter N/A 0.032 in | Material N/A Brass | CV N/A 0.024 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-33-0-BR | Orifice Diameter N/A 0.033 in | Material N/A Brass | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-33-2-BR | Orifice Diameter N/A 0.033 in | Material N/A Brass | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-33-10-BR | Orifice Diameter N/A 0.033 in | Material N/A Brass | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-33-0-SS | Orifice Diameter N/A 0.033 in | Material N/A 303 SS | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-33-2-SS | Orifice Diameter N/A 0.033 in | Material N/A 303 SS | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLC-33-10-SS | Orifice Diameter N/A 0.033 in | Material N/A 303 SS | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A None |
Add To Cart
Request Quote |
FIFLCS-33-0-BR | Orifice Diameter N/A 0.033 in | Material N/A Brass | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-33-2-BR | Orifice Diameter N/A 0.033 in | Material N/A Brass | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-33-10-BR | Orifice Diameter N/A 0.033 in | Material N/A Brass | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 10 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-33-0-SS | Orifice Diameter N/A 0.033 in | Material N/A 303 SS | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 0 psig | Screened N/A Screened |
Add To Cart
Request Quote |
FIFLCS-33-2-SS | Orifice Diameter N/A 0.033 in | Material N/A 303 SS | CV N/A 0.025 | Maximum Fitting PRESSURE N/A 200 psig | DIFFERENTIAL CRACK PRESSURE N/A 2 psig | Screened N/A Screened |
Add To Cart
Request Quote |