The restrictors incorporate a precision synthetic sapphire orifice which is fitted within a main body. The sapphire orifice is a stable, accurate flow restrictor. Standard sizes range from .0012" to .0252" orifice diameter in 32 increments.
Unit of Measure

Material

N/A Nylon

Nominal Orifice Size

N/A 13

CV

N/A 0.0043

Orifice Material

N/A Synthetic Sapphire

Maximum Operating Pressure Gauge

N/A 100 psig

Connection A

N/A .128" Press-Fit Insert

Screened

N/A None

Orifice Diameter

N/A 0.0051 in0.13 mm

Total Length

N/A 0.306 in

Maximum Outside Diameter

N/A 0.129 in

Minimum Outside Diameter

N/A 0.128 in

Orifice Diameter Accuracy

N/A ±0.0003 in

Press Fit into Bore

N/A 0.125 to 0.126 in

N/A

  • Precision Flow Control - Gases or Liquids
  • Accurate Timing in Pneumatic or Hydraulic Circuits
  • Pressure Dividing Circuits and Pneumatic Resistance Bridges
  • Impedance Matching
  • Uni-directional Flow

Air Flow at Pressure - Standard Liters Per Minute (SLPM)_Sapphire

N/A 1 psig: 0.068 5 psig: 0.159 10 psig: 0.228 15 psig: 0.285 20 psig: 0.337 25 psig: 0.389 30 psig: 0.440 40 psig: 0.543 50 psig: 0.652 60 psig: 0.751 70 psig: 0.855 80 psig: 0.959 90 psig: 1.06 100 psig: 1.17

Air Flow at Vacuum - Standard Liters Per Minute (SLPM)_Sapphire

N/A 5 In. Hg.: 0.100 10 In. Hg.: 0.128

Air Flow at Vacuum, Choked Flow - Standard Liters Per Minute (SLPM)_Sapphire

N/A 15 In. Hg.: 0.138 20 In. Hg.: 0.138 30 In. Hg.: 0.138

Air Flow at Pressure - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 1 psig: 0.144 5 psig: 0.337 10 psig: 0.483 15 psig: 0.604 20 psig: 0.714 25 psig: 0.824 30 psig: 0.932 40 psig: 1.15 50 psig: 1.38 60 psig: 1.59 70 psig: 1.81 80 psig: 2.03 90 psig: 2.25 100 psig: 2.47

Air Flow at Vacuum - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 5 In. Hg.: 0.212 10 In. Hg.: 0.271

Air Flow at Vacuum, Choked Flow - Standard Cu. Ft. Per Hour (SCFH)_Sapphire

N/A 15 In. Hg.: 0.292 20 In. Hg.: 0.292 30 In. Hg.: 0.292