- The restrictors incorporate a precision synthetic sapphire orifice which is fitted within a main body. The sapphire orifice is a stable, accurate flow restrictor. Standard sizes range from .0012" to .0252" orifice diameter in 32 increments.
Unit of Measure
Material |
N/A Nylon |
Nominal Orifice Size |
N/A 6 |
CV |
N/A 0.0012 |
Orifice Material |
N/A Synthetic Sapphire |
Maximum Operating Pressure Gauge |
N/A 100 psig |
Connection A |
N/A .134" Press-Fit Insert |
Screened |
N/A None |
Orifice Diameter |
N/A 0.0024 in0.06 mm |
Total Length |
N/A 0.306 in |
Maximum Outside Diameter |
N/A 0.137 in |
Minimum Outside Diameter |
N/A 0.134 in |
Orifice Diameter Accuracy |
N/A ±0.0003 in |
Press Fit into Bore |
N/A 0.132 to 0.133 in |
N/A
|
Air Flow at Pressure - Standard Liters Per Minute (SLPM)_Sapphire |
N/A 1 psig: 0.014 5 psig: 0.036 10 psig: 0.049 15 psig: 0.062 20 psig: 0.074 25 psig: 0.087 30 psig: 0.098 40 psig: 0.122 50 psig: 0.147 60 psig: 0.171 70 psig: 0.195 80 psig: 0.200 90 psig: 0.244 100 psig: 0.269 |
Air Flow at Vacuum - Standard Liters Per Minute (SLPM)_Sapphire |
N/A 5 In. Hg.: 0.020 10 In. Hg.: 0.027 |
Air Flow at Vacuum, Choked Flow - Standard Liters Per Minute (SLPM)_Sapphire |
N/A 15 In. Hg.: 0.030 20 In. Hg.: 0.030 30 In. Hg.: 0.030 |
Air Flow at Pressure - Standard Cu. Ft. Per Hour (SCFH)_Sapphire |
N/A 1 psig: 0.030 5 psig: 0.075 10 psig: 0.104 15 psig: 0.131 20 psig: 0.157 25 psig: 0.184 30 psig: 0.208 40 psig: 0.258 50 psig: 0.311 60 psig: 0.362 70 psig: 0.413 80 psig: 0.424 90 psig: 0.517 100 psig: 0.570 |
Air Flow at Vacuum - Standard Cu. Ft. Per Hour (SCFH)_Sapphire |
N/A 5 In. Hg.: 0.043 10 In. Hg.: 0.057 |
Air Flow at Vacuum, Choked Flow - Standard Cu. Ft. Per Hour (SCFH)_Sapphire |
N/A 15 In. Hg.: 0.063 20 In. Hg.: 0.063 30 In. Hg.: 0.063 |