Precision orifice assemblies that adapt to common fittings used in the process industry. Press-fit inserts are used with standard compression tube fittings to form a precision orifice assembly. The fittings shown here are for 1/4" OD tubing, or 3/16" OD tubing.
Unit of Measure

Material

N/A 316 SS

Nominal Orifice Size

N/A 25

CV

N/A 0.014

Maximum Operating Pressure

N/A 4000 psig

Maximum Pressure Differential

N/A 1000 psig

Connection A

N/A 1/4" OD Tube Compression

Connection B

N/A 1/4" OD Tube

Screened

N/A None

Orifice Diameter

N/A 0.025 in

Orifice Diameter Accuracy

N/A ±0.0005 in

Outside Diameter

N/A 0.37 in

Shank Length

N/A 0.74 in

Total Length

N/A 0.970 in

N/A

    Compression fittings are used with a metal or rigid plastic tubing. These fittings are used in instrumentation for process control systems. The nature of the connectors allow for easy disassembly and re-assembly without the need for teflon tape or sealants.

N/A

  • High Pressure Capability
  • Bi-directional Flow
  • Economical Precision Orifice
  • Repeatable Orifice Size and Shape
  • Predictable Flow Rate

Air Flow at Pressure - Standard Cu. Ft. Per Hour (SCFH)

N/A 1 psig: 3.54 5 psig: 8.12 10 psig: 11.8 15 psig: 14.7 20 psig: 17.3 25 psig: 19.9 30 psig: 22.5 40 psig: 27.5 50 psig: 32.6 60 psig: 37.5 70 psig: 42.6 80 psig: 47.7 90 psig: 52.8 100 psig: 58.1

Air Flow at Vacuum - Standard Cu. Ft. Per Hour (SCFH)

N/A 5 In. Hg.: 5.25 10 In. Hg.: 6.63

Air Flow at Vacuum, Choked Flow - Standard Cu. Ft. Per Hour (SCFH)

N/A 15 In. Hg.: 7.08 20 In. Hg.: 7.08 30 In. Hg.: 7.08

Air Flow at Pressure - Standard Liters Per Minute (SLPM)

N/A 1 psig (6.9 kPag): 1.67 5 psig (34.5 kPag): 3.83 10 psig (69.0 kPag): 5.55 15 psig (103.4 kPag): 6.95 20 psig (137.9 kPag): 8.15 25 psig (172.4 kPag): 9.38 30 psig (206.9 kPag): 10.6 40 psig (275.8 kPag): 13.0 50 psig (344.8 kPag): 15.4 60 psig (413.7 kPag): 17.7 70 psig (482.7 kPag): 20.1 80 psig (551.6 kPag): 22.5 90 psig (620.6 kPag): 24.9 100 psig (689.5 kPag): 27.4

Air Flow at Vacuum - Standard Liters Per Minute (SLPM)

N/A 5 In. Hg. (127 Mm. Hg.): 2.48 10 In. Hg. (254 Mm. Hg.): 3.13

Air Flow at Vacuum, Choked Flow - Standard Liters Per Minute (SCFH)

N/A 15 In. Hg. (381 Mm. Hg.): 3.34 20 In. Hg. (508 Mm. Hg.): 3.34 30 In. Hg. (762 Mm. Hg.): 3.34

Water Flow - Gallons/minute (GPM)

N/A 1 psig: 0.014 2 psig: 0.020 3 psig: 0.024 4 psig: 0.028 5 psig: 0.031 6 psig: 0.034 7 psig: 0.037 8 psig: 0.040 9 psig: 0.042 10 psig: 0.044 15 psig: 0.054 20 psig: 0.063 30 psig: 0.077 40 psig: 0.089 50 psig: 0.099 60 psig: 0.108 70 psig: 0.117 80 psig: 0.125 90 psig: 0.133 100 psig: 0.140

Water Flow - Liters/minute (LPM)

N/A 1 psig (6.9 kPag): 0.053 2 psig (13.8 kPag): 0.075 3 psig (20.7 kPag): 0.092 4 psig (27.6 kPag): 0.106 5 psig (34.5 kPag): 0.119 6 psig (41.4 kPag): 0.119 7 psig (48.3 kPag): 0.140 8 psig (55.2 kPag): 0.150 9 psig (62.1 kPag): 0.159 10 psig (69 kPag): 0.168 15 psig (103.4 kPag): 0.205 20 psig (137.9 kPag): 0.237 30 psig (206.9 kPag): 0.290 40 psig (275.8 kPag): 0.335 50 psig (344.8 kPag): 0.375 60 psig (413.7 kPag): 0.411 70 psig (482.7 kPag): 0.443 80 psig (551.6 kPag): 0.474 90 psig (620.6 kPag): 0.503 100 psig (689.5 kPag): 0.530

Flow Data Status

N/A Generic